{"product_id":"2787-2157-pro-2-jednofazovy-napajaci-zdroj-48v-10a-480w","title":"2787-2157 Pro 2 – single-phase power supply 48 V DC, 10 A, 480 W","description":"\u003cp\u003e\u003cstrong\u003e2787-2157 Pro 2\u003c\/strong\u003e is a single-phase industrial Wago DIN rail power supply with an output of \u003cstrong\u003e48 V DC \/ 10 A\u003c\/strong\u003e and a rated power of \u003cstrong\u003e480 W\u003c\/strong\u003e. It provides a stable supply for control systems, sensors, interfaces and other devices operating at 48 V DC. The adjustable 48–56 V DC output, short-term current reserve and integrated diagnostics allow the supply to be adapted to the application.\u003c\/p\u003e\n\u003cp\u003eThe power supply operates from a 100–240 V AC mains supply. Its 70 mm wide metal housing saves space in the control cabinet. Status LEDs and control buttons allow the load to be checked and the output to be adjusted directly on the device.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerBoost:\u003c\/strong\u003e short-term output current of up to 15 A for 5 s, equivalent to 150% of the rated current, to handle startup loads and brief power peaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopBoost:\u003c\/strong\u003e a current pulse of up to 60 A for 15 ms to support rapid tripping of downstream protective devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable overload behaviour:\u003c\/strong\u003e constant current mode, time-limited mode, repeated hiccup restart or electronic circuit protection, depending on the configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 digital input and 1 digital output:\u003c\/strong\u003e remote control and operating status indication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual diagnostics:\u003c\/strong\u003e five LEDs for DC OK, load level, warnings and fault states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+\/− control buttons:\u003c\/strong\u003e output voltage adjustment and control of operating functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel and series operation:\u003c\/strong\u003e multiple power supplies can be connected, subject to the conditions for the selected connection method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePluggable connectors:\u003c\/strong\u003e CAGE CLAMP spring connection technology for installation and device replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural convection cooling:\u003c\/strong\u003e fanless operation when mounted on a horizontal DIN rail in the specified orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanically isolated SELV\/PELV output\u003c\/strong\u003e in accordance with EN 61010-2-201 \/ UL 61010-2-201, with short-circuit, overload and overtemperature protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabelling:\u003c\/strong\u003e slot for Wago WMB markers and marking strips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControl and monitoring\u003c\/h3\u003e\n\u003cp\u003eThe digital input DI controls output activation and standby mode. The digital output DO can be configured, for example, to signal DC OK, a preset load threshold being exceeded or the power supply being switched off. Five LEDs indicate the supply status and load levels of 25%, 50%, 75% and 100%.\u003c\/p\u003e\n\u003ch3\u003eCommunication and configuration\u003c\/h3\u003e\n\u003cp\u003eThe communication interface allows power supply parameters to be configured and operating data to be monitored. \u003cstrong\u003eBus connection requires a separately purchased communication module; modules are not included with the power supply.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIO-Link:\u003c\/strong\u003e communication module 2789-9080.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus RTU:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/2789-9015-communication-module-modbus-rtu-pro-2\"\u003ecommunication module 2789-9015\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP\/UDP:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/2789-9052-communication-module-modbus-tcp-udp-pro-2\"\u003ecommunication module 2789-9052\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP and MQTT:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/2789-9023-communication-module-ethernet-ip-mqtt-pro-2\"\u003ecommunication module 2789-9023\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration via computer:\u003c\/strong\u003e USB communication cable 750-923 and Wago Interface Configuration software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen using Ethernet modules 2789-9052 or 2789-9023, the maximum operating temperature of the combined assembly is \u003cstrong\u003e+55 °C\u003c\/strong\u003e. Firmware requirements are listed in the description of the respective module.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated input voltage:\u003c\/strong\u003e 1 × 100–240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage range:\u003c\/strong\u003e 1 × 90–264 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains frequency:\u003c\/strong\u003e 50–60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output voltage:\u003c\/strong\u003e 48 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage adjustment:\u003c\/strong\u003e 48–56 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output current:\u003c\/strong\u003e 10 A at 48 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated power:\u003c\/strong\u003e 480 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerBoost:\u003c\/strong\u003e up to 15 A \/ 5 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopBoost:\u003c\/strong\u003e up to 60 A \/ 15 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual ripple:\u003c\/strong\u003e ≤ 70 mV, peak-to-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower factor correction:\u003c\/strong\u003e active PFC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains failure hold-up time:\u003c\/strong\u003e ≥ 24 ms (230 V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital signals:\u003c\/strong\u003e 1 × DI and 1 × DO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of protection and protection class:\u003c\/strong\u003e IP20, class I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions W × H × D:\u003c\/strong\u003e 70 × 130 × 130 mm; height without connectors, depth measured from the top edge of the DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight with connectors:\u003c\/strong\u003e 166 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1450 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e −25 to +70 °C; type-tested startup at −40 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e −40 to +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5–96%, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum altitude:\u003c\/strong\u003e 5 000 m, with the applicable derating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and sizing\u003c\/h3\u003e\n\u003cp\u003eAt ambient temperatures above +55 °C, the permissible power must be reduced by 3% for each additional 1 °C. Altitude, the selected output voltage and the conditions of the specific installation must also be taken into account. When increasing the output voltage, reduce the continuous current so that the rated power is not exceeded. The short-term TopBoost and PowerBoost functions do not replace correct sizing of the power supply for continuous loads.\u003c\/p\u003e\n\u003cp\u003eMount the power supply on a horizontal DIN rail with the supply terminals at the bottom. Leave sufficient space for natural airflow and use conductors and protective devices suitable for the load. For parallel or series connections, follow the diagrams and conditions in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.wago.com\/global\/power-supply-modules\/power-supply\/p\/2787-2157\" target=\"_blank\" rel=\"noopener\" style=\"color: #ff2a00;\"\u003eManufacturer information\u003c\/a\u003e | \u003ca href=\"https:\/\/www.wago.com\/global\/download\/public\/7258340_EN-en-V102\/m27872157_00000000_0en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperating instructions (EN)\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Wago","offers":[{"title":"Default Title","offer_id":60667097055577,"sku":"2787-2157","price":621.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/5970\/3779\/files\/wago-2787-2157-pro2.webp?v=1795438149","url":"https:\/\/www.knxsolution.sk\/en\/products\/2787-2157-pro-2-single-phase-power-supply-48v-10a-480w","provider":"KNXSolution","version":"1.0","type":"link"}