{"product_id":"855-305-prudovy-transformator-5-a-26-mm-trieda-0-5","title":"855-305 Current transformer 100–750\/5 A, Ø 26 mm, class 0.5","description":"\u003cp\u003e\u003cstrong\u003eWago 855-305\u003c\/strong\u003e is a range of inductive current transformers with a \u003cstrong\u003esolid, closed core\u003c\/strong\u003e for indirect AC current measurement. The selected variants convert a primary current of \u003cstrong\u003e100 to 750 A into a rated secondary current of 5 A\u003c\/strong\u003e with accuracy class \u003cstrong\u003e0.5\u003c\/strong\u003e. They are suitable accessories for Wago 879-3040 and 879-3041 energy meters when monitoring electricity consumption and energy flows.\u003c\/p\u003e\n\u003cp\u003eThe 855-305 range has an opening for round conductors up to \u003cstrong\u003e26 mm\u003c\/strong\u003e in diameter and can also be fitted over a suitably sized busbar. Screwless CAGE CLAMP terminals provide a reliable secondary circuit connection. The mechanically robust design with high connection retention force withstands vibration and shock.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eRated secondary current of 5 A\u003c\/strong\u003e for connection to a compatible energy meter.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAccuracy class 0.5\u003c\/strong\u003e and conformity assessment according to Module D for the listed order numbers.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAC current measurement:\u003c\/strong\u003e frequency 50–60 Hz; the transformer is not intended for DC current measurement.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eContinuous current carrying capacity of 120 %\u003c\/strong\u003e of the rated primary current.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAGE CLAMP:\u003c\/strong\u003e screwless connection of secondary conductors.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSeveral mounting options:\u003c\/strong\u003e on a mounting plate, round conductor or busbar; on a DIN rail using the separately available \u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/855-9900-din-rail-adapter-for-current-transformers\" title=\"855-9900 DIN rail adapter for current transformers\"\u003e855-9900\u003c\/a\u003e adapter.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAvailable variants\u003c\/h3\u003e\u003cp\u003eSelect the required current ratio from the options. Each variant is \u003cstrong\u003eone transformer\u003c\/strong\u003e:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e100\/5 A\u003c\/strong\u003e – 855-305\/100-209; rated burden 2.5 VA; weight 293 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e150\/5 A\u003c\/strong\u003e – 855-305\/150-209; rated burden 2.5 VA; weight 280 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e200\/5 A\u003c\/strong\u003e – 855-305\/200-509; rated burden 5 VA; weight 230 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e250\/5 A\u003c\/strong\u003e – 855-305\/250-509; rated burden 5 VA; weight 230 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e300\/5 A\u003c\/strong\u003e – 855-305\/300-509; rated burden 5 VA; weight 230 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e400\/5 A\u003c\/strong\u003e – 855-305\/400-509; rated burden 5 VA; weight 230 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e500\/5 A\u003c\/strong\u003e – 855-305\/500-509; rated burden 5 VA; weight 230 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e600\/5 A\u003c\/strong\u003e – 855-305\/600-509; rated burden 5 VA; weight 230 g\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e750\/5 A\u003c\/strong\u003e – 855-305\/750-509; rated burden 5 VA; weight 230 g\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatible energy meters\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/879-3040-modbus-m-bus-current-transformer-energy-meter-mid\"\u003e879-3040 – Modbus \/ M-Bus energy meter for current transformers, MID\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/879-3041-modbus-m-bus-current-transformer-energy-meter-mid-metas\"\u003e879-3041 – Modbus \/ M-Bus energy meter for current transformers, MID\/METAS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eStandard three-phase, four-wire measurement requires \u003cstrong\u003e3 transformers with the same ratio, one for each phase\u003c\/strong\u003e. Set the meter's secondary current to 5 A and its primary current to match the selected variant.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e window-type measuring transformer with a solid, closed core\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRound conductor diameter:\u003c\/strong\u003e maximum 26 mm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBusbar dimensions:\u003c\/strong\u003e 30 × 10 mm, 25 × 12 mm or 20 × 20 mm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated secondary current:\u003c\/strong\u003e 5 A\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated burden:\u003c\/strong\u003e 2.5 VA or 5 VA depending on the variant\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e 0.5\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated frequency:\u003c\/strong\u003e 50–60 Hz\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated continuous thermal current:\u003c\/strong\u003e 1.2 × rated primary current\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated short-time thermal current:\u003c\/strong\u003e 60 × rated primary current for 1 s, maximum 100 kA for 1 s\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHighest voltage for equipment Uₘ:\u003c\/strong\u003e 1.2 kV AC\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTest voltage:\u003c\/strong\u003e 6 kV AC, 50 Hz, 1 min\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInsulation class:\u003c\/strong\u003e E\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSecondary connection:\u003c\/strong\u003e CAGE CLAMP, solid and fine-stranded conductors 0.08–4 mm²; stripping length 9–10 mm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 60 × 80.9 × 52 mm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e −5 to +50 °C\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e −25 to +70 °C\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum altitude:\u003c\/strong\u003e 1,000 m\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 61869-1 and EN 61869-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSelection and installation\u003c\/h3\u003e\u003cp\u003eSelect the ratio according to the rated current of the measured circuit and check that the conductor or busbar fits through the transformer opening. The secondary wiring together with the meter must be suitable for the rated burden of the selected variant. DIN rail mounting requires the \u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/855-9900-din-rail-adapter-for-current-transformers\" title=\"855-9900 DIN rail adapter for current transformers\"\u003e855-9900\u003c\/a\u003e adapter, which is ordered separately.\u003c\/p\u003e\u003cp\u003eThe transformer has a closed core, so the conductor or busbar must be passed through its opening during installation. Observe the P1\/P2 and S1\/S2 polarity markings. \u003cstrong\u003eThe secondary circuit must never be left open while current is flowing through the primary conductor.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wago.com\/global\/energy-measurement-technology\/plug-in-current-transformer\/p\/855-305_100-209\" target=\"_blank\" rel=\"noopener\" style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eManufacturer information\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wago.com\/global\/download\/public\/12070\/99700966_08550x01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperating instructions (DE\/EN)\u003c\/a\u003e\u003c\/p\u003e","brand":"Wago","offers":[{"title":"100\/5 A","offer_id":60571438023001,"sku":"855-305\/100-209","price":283.0,"currency_code":"EUR","in_stock":true},{"title":"150\/5 A","offer_id":60571438055769,"sku":"855-305\/150-209","price":283.0,"currency_code":"EUR","in_stock":true},{"title":"200\/5 A","offer_id":60571438088537,"sku":"855-305\/200-509","price":283.0,"currency_code":"EUR","in_stock":true},{"title":"250\/5 A","offer_id":60571438121305,"sku":"855-305\/250-509","price":246.0,"currency_code":"EUR","in_stock":true},{"title":"300\/5 A","offer_id":60571438154073,"sku":"855-305\/300-509","price":253.0,"currency_code":"EUR","in_stock":true},{"title":"400\/5 A","offer_id":60571438186841,"sku":"855-305\/400-509","price":253.0,"currency_code":"EUR","in_stock":true},{"title":"500\/5 A","offer_id":60571438219609,"sku":"855-305\/500-509","price":253.0,"currency_code":"EUR","in_stock":true},{"title":"600\/5 A","offer_id":60571438252377,"sku":"855-305\/600-509","price":318.0,"currency_code":"EUR","in_stock":true},{"title":"750\/5 A","offer_id":60571438285145,"sku":"855-305\/750-509","price":318.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/5970\/3779\/files\/wago-855-305_100-209-1.webp?v=1795106482","url":"https:\/\/www.knxsolution.sk\/en\/products\/855-305-current-transformer-5-a-26-mm-class-0-5","provider":"KNXSolution","version":"1.0","type":"link"}