{"product_id":"879-3041-modbus-m-bus-elektromer-pre-transformatory-mid-metas","title":"879-3041 Modbus \/ M-Bus energy meter for 1 A \/ 5 A current transformers MID\/METAS","description":"\u003cp\u003e\u003cstrong\u003eWago 879-3041\u003c\/strong\u003e is a three-phase energy meter for \u003cstrong\u003eindirect measurement using current transformers with a secondary current of 1 A or 5 A\u003c\/strong\u003e. In 3 × 230\/400 V AC networks, it records imported and exported active and reactive energy and measures the electrical quantities of each phase. It is suitable for monitoring consumption in buildings, production equipment and distribution boards where the measured current is fed to the meter through external current transformers.\u003c\/p\u003e\n\u003cp\u003eThe integrated \u003cstrong\u003eModbus RTU over RS-485 and M-Bus\u003c\/strong\u003e interfaces allow data to be transmitted to a building management or energy management system. The backlit LCD displays measured values directly on the device. The \u003cstrong\u003e2PU CT\u003c\/strong\u003e design occupies two modules on the DIN rail, while Push-in CAGE CLAMP terminals with levers simplify wiring.\u003c\/p\u003e\n\u003ch3\u003eMeasurement, tariffs and communication\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMeasurement using 1 A or 5 A current transformers:\u003c\/strong\u003e the ratio is set according to the rated values of the transformers used.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBidirectional measurement:\u003c\/strong\u003e separate recording of imported and exported active and reactive energy.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInstantaneous electrical quantities:\u003c\/strong\u003e voltage and current of each phase, active, reactive and apparent power, power factor and mains frequency.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFour tariffs:\u003c\/strong\u003e the 230 V AC tariff input switches between T1\/T2; T3\/T4 can be selected using the control buttons or via Bluetooth, Modbus or M-Bus.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTwo configurable S0 pulse outputs:\u003c\/strong\u003e transmission of energy data to a compatible counter or control system.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLocal and wireless configuration:\u003c\/strong\u003e touch-sensitive control buttons and the WAGO Energy Meter Configurator app via Bluetooth.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePowered from the measured circuit:\u003c\/strong\u003e the meter does not require a separate auxiliary power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDesign and certification\u003c\/h3\u003e\u003cp\u003eModel 879-3041 is \u003cstrong\u003eMID\/METAS\u003c\/strong\u003e certified. Active energy is measured with accuracy class B according to EN 50470-3. The compact 2PU CT design is intended for mounting on a 35 mm DIN rail.\u003c\/p\u003e\n\u003ch3\u003eRequired accessories to purchase separately (not included)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent transformers suitable for the measured circuit.\u003c\/strong\u003e A standard three-phase, four-wire installation requires \u003cstrong\u003e3 transformers with the same ratio, one for each phase\u003c\/strong\u003e. The following recommended ranges have a 5 A secondary current and accuracy class 0.5:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/855-305-current-transformer-5-a-26-mm-class-0-5\"\u003e855-305 – current transformers 100 to 750 A \/ 5 A, Ø 26 mm opening\u003c\/a\u003e; 9 variants according to the primary current.\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.knxsolution.sk\/en\/products\/855-405-current-transformer-5-a-32-mm-class-0-5\"\u003e855-405 – current transformers 200 to 750 A \/ 5 A, Ø 32 mm opening\u003c\/a\u003e; 7 variants according to the primary current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSelect the ratio according to the current of the measured circuit and the opening according to the dimensions of the conductor or busbar. When designing the secondary circuit, take into account the transformer's rated burden and the load imposed by the connecting leads and meter. The corresponding ratio and secondary current must be set in the meter.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMeasurement method:\u003c\/strong\u003e indirect, using external current transformers; two-wire, three-wire and four-wire networks according to the wiring diagram\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 3 × 230\/400 V AC, tolerance ±20 %\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTransformer secondary current:\u003c\/strong\u003e selectable 1 A or 5 A; maximum input current 5 A\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePrimary current setting:\u003c\/strong\u003e 1–9,999 A with a 1 A secondary current or 5–9,995 A with a 5 A secondary current\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e rated 50 Hz, operating range 45–60 Hz\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e Modbus RTU, two-wire RS-485; M-Bus; Bluetooth\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e 1× 230 V AC tariff input\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e 2× configurable S0 pulse output\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e backlit LCD\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail, width 2 modules\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 36 × 140 × 63 mm including covers; height without covers 97 mm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDegree of protection:\u003c\/strong\u003e IP51 at the front, IP20 in the connection area\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eProtection class:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e −40 to +70 °C\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHousing material:\u003c\/strong\u003e polycarbonate PC 940A\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 165 g\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConnection and configuration\u003c\/h3\u003e\u003cp\u003eThe voltage, current, communication and tariff input terminals use Push-in CAGE CLAMP with levers. They accept solid and fine-stranded conductors of 0.2–4 mm², or 0.25–2.5 mm² with ferrules; the stripping length is 9–11 mm. Wiring must match the selected network and the polarity of the current transformers.\u003c\/p\u003e\u003cp\u003eThe transformer ratio can be changed a maximum of seven times in the protected settings. The meter retains a history of ratio changes and the corresponding energy registers, so the correct ratio should be selected during commissioning.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wago.com\/global\/energy-measurement-technology\/energy-meter-mid25\/p\/879-3041\" target=\"_blank\" rel=\"noopener\" style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eManufacturer information\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wago.com\/global\/download\/public\/5937710_EN-en-V18\/m087930x0_00000000_0en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperating instructions (EN)\u003c\/a\u003e\u003c\/p\u003e","brand":"Wago","offers":[{"title":"Default Title","offer_id":60571432386905,"sku":"879-3041","price":265.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/5970\/3779\/files\/wago-879-3041-1.webp?v=1795106475","url":"https:\/\/www.knxsolution.sk\/en\/products\/879-3041-modbus-m-bus-current-transformer-energy-meter-mid-metas","provider":"KNXSolution","version":"1.0","type":"link"}